Physical fields

The quantities a model must reproduce are fixed before the model is chosen.

Outcome: Name the surface, volume and integral quantities a surrogate can predict; use non-dimensional quantities such as Cp, CL, Re and Mach; compute an integral quantity from a predicted field.

Builds on What a surrogate is

A surrogate is only useful if it predicts what an engineer would read from the simulation. Many of those quantities are fields. Others are single numbers taken from a field, such as the lift or the peak temperature.

DefinitionField

A quantity with a value at every point, such as the pressure over a wing, the temperature across a chip or the stress in a bracket.
Cp -1.5 (suction)+1
Figure 2-1. Pressure coefficient Cp on the whole surface from the solver, α 4°, sweep 28°: the field a surrogate has to reproduce.

Figure 2-1 shows one, the surface pressure of the course’s aircraft. The quantities an engineer reads fall into three groups:

  • Surface: pressure, wall shear stress, heat flux. Loads, lift and drag, hot spots: what designers read or integrate.
  • Volume: velocity, pressure, vorticity, temperature, turbulence quantities. Wakes, vortices, separation, mixing: what explains the surface numbers.
  • Integral: lift, drag and moment coefficients, efficiency. The few numbers that often decide a design; scalar surrogates stop here.

Which of them to predict follows from the decision the model has to support: load distributions need accurate surface fields, explaining a design needs the volume, and a quick screening may only need the integrals.

Non-dimensional quantities

Aerodynamicists rarely predict pressure in pascals. They measure it against the undisturbed air far ahead of the body (the free stream) and divide by the dynamic pressure 12ρV2\tfrac{1}{2}\rho V^2, the rise in pressure where incompressible flow is brought to rest. The result is the pressure coefficient CpC_p:

Cp=p−p∞12 ρ∞V∞2C_p = \frac{p - p_\infty}{\tfrac{1}{2}\, \rho_\infty V_\infty^2}
(2-1)
p∞,ρ∞,V∞p_\infty, \rho_\infty, V_\infty: free-stream pressure, density and speed. In incompressible flow Cp=1C_p = 1 at a stagnation point (above 1 in compressible flow: about 1.02 at Mach 0.3, 1.17 at Mach 0.8).

Cp=0C_p = 0 means free-stream pressure. Positive values press harder, as at the nose, where the air stops (a stagnation point). Negative values press less: suction, as over the top of a wing.

The same idea gives the lift and drag coefficients CLC_L and CDC_D (force divided by dynamic pressure and a reference area). It also gives the numbers that describe the flow regime: the Reynolds number Re=ρVL/μ\mathrm{Re} = \rho V L / \mu (inertia against viscosity; LL is a reference length and μ\mu the dynamic viscosity) and the Mach number M=V/aM = V / a (speed against the speed of sound aa).

This helps a surrogate in three ways. Runs of one shape at one attitude, at different speeds or sizes but the same Re\mathrm{Re} and MM, give the same CpC_p field, so the model has less to learn. Values are of order one, which suits fitting (more in normalising). And a prediction made at one speed and size holds at any other with the same Re\mathrm{Re} and MM.

The reason is dimensional analysis. By the Buckingham Π\Pi theorem (1914), a physical relation among nn quantities whose units involve kk independent dimensions can be written as a relation among n−kn - k dimensionless groups. For steady incompressible flow past bodies of one shape, at the same attitude to the flow, the flow in units of LL and VV then depends on Re\mathrm{Re} alone: a body ten times larger at the same Re\mathrm{Re} has the same CpC_p field, a property called dynamic similarity. In compressible flow the Mach number joins Re\mathrm{Re}. Size and speed should therefore reach a model through Re\mathrm{Re} and MM rather than as metres and metres per second.

Integrals come from fields

Lift, drag and moments are integrals of the surface fields: pressure and, in viscous flow, wall shear stress. For lift the pressure dominates. It pushes on every panel along its inward normal; summing those forces and keeping the component in the lift direction gives CLC_L:

CL=−1S∑iCp,i nL,i AiC_L = -\frac{1}{S} \sum_i C_{p,i}\, n_{L,i}\, A_i
(2-2)
SS: reference area. AiA_i: the area of panel ii. nL,in_{L,i}: the component of its outward unit normal in the lift direction. The sum runs over all surface panels.
Example 2-1. The lift coefficient from surface pressure, with NumPy
import numpy as np

# One run on a coarse surface mesh: 4 panels on top, 4 below.
# Per panel: pressure coefficient, area (m²), outward normal.
cp = np.array([-1.1, -0.8, -0.5, -0.2, 0.3, 0.15, 0.05, 0.0])
area = np.full(8, 0.25)
up, down = [0, 0, 1], [0, 0, -1]
normal = np.array([up] * 4 + [down] * 4, dtype=float)1

# Reference area in m².
S_ref = 1.0
force = cp[:, None] * normal * area[:, None]2
coeffs = -force.sum(axis=0) / S_ref3

# Lift: the component normal to the flow (here z).
CL = coeffs[2]
print(f"CL = {CL:.3f}")  # CL = 0.775
  1. Outward unit normals: up on the four upper panels, down on the four lower ones.
  2. Each panel’s Cp,i Ai niC_{p,i}\, A_i\, \mathbf{n}_i: its pressure force divided by the dynamic pressure, with the sign reversed (callout 3 restores it). [:, None] turns the per-panel values into a column, so each one scales its panel’s normal.
  3. The sum over the panels, divided by SS, with the minus sign of Equation 2-2: pressure pushes along the inward normal.

Example 2-1 prints CL = 0.775. Suction on top (negative CpC_p, outward normal up) and overpressure underneath (positive CpC_p, normal down) both push upward. With the flow at an angle, the lift direction, perpendicular to the free stream, replaces the vertical axis.

A full-field model gives the integrals by summing over the surface, provided it predicts every term. A model of CLC_L alone cannot say where the lift comes from. Small field errors can also add up in an integral, so later lessons check both (measuring error).

The site’s surrogate predicts CpC_p over the surface, the field of Figure 2-1. The surface pressure explains the lift. The flow around a wing section shows where the air accelerates and stagnates. A plane behind the wing shows the air pushed downwards (downwash) and the swirls trailing from the tips (tip vortices), which together cause induced drag, the drag that comes with producing lift. The surface surrogate is in testing on unseen designs, the section and wake surrogates in decoders and volume fields.

The solver behind this course

In CFD, field and integrals come from one solution and are consistent. The course’s solver is a deterministic potential-flow model, which treats the air as frictionless and incompressible: a vortex lattice for the lift of each wing strip, a 2D panel method (Hess–Smith) for that strip’s surface pressure, and slender-body theory for the fuselage. It computes lift and surface pressure separately, so lift integrated from its CpC_p does not match its CLC_L exactly. It runs in seconds and has no iterations to converge, but it cannot show the boundary layer (the thin layer of slowed air along the skin), a wing stalling, or the effects near the speed of sound (transonic flow) that wing sweep exists to delay: at α\alpha of 10° to 12°, used later as an extrapolation test, it can be far from a real wing. Every error quoted for the course’s aircraft is against this idealised solver.

Check yourself

  1. 1A surrogate of CL alone was built from 200 runs. The question is where on the wing the lift is lost at high sweep. What can the model say?
  2. 2The runs cover free-stream speeds from 20 to 60 m/s and the target is surface pressure in pascals. What does switching the target to Cp gain?
  3. 3A panel on the lower surface has Cp = +0.3 and an outward normal pointing down. With CL = −(1/S) Σ Cp · n_L · A, does it add to or take away from lift?
A study ranks designs by drag only. Is a volume-field surrogate needed?

Probably not. A scalar drag model, or a surface model of both pressure and wall shear, is often enough; the volume helps more to explain a design than to rank it.

Two steady incompressible flows past the same shape at the same attitude, one body ten times larger, at the same Re. How do their Cp fields compare, and how should size reach a model?

They are the same at corresponding points: by dynamic similarity, the flow in units of the body length and the free-stream speed depends only on Re for a given shape and attitude. So size should reach the model through Re, not through lengths in metres.

Go further